Tonight, when I went to update the database on my telescope, it informed me that there was a new version of the Meade Autostar software - version 59Ef. I went ahead and installed it and it bombed my 497 handbox. I booted the handbox in load mode and kept on trying to load it, but it bombed every time. I then noticed that the previous version, 43Eg, as well as all other previous versions were exactly 1028 KB while 59Ef was 1031KB. I don't know for sure that this is significant, but I suspect that the Handbox may only have 1028KB of memory. I've found that other folks have had this version bomb their handbox too, while I've seen no one who has successfully loaded it. Incidentally, in order to load the software onto a hosed handbox, you turn off the telescope, then hold down the ENTER and PAGE DOWN (next to the question mark, not the down arrow) and then turn it on. It will go into a loading mode into which you can load the working version, 43Eg. I plan on contacting Meade and letting them know so they can get it updated.